Changes between Version 12 and Version 13 of Mendel3DPrinter


Ignore:
Timestamp:
Mar 10, 2018, 1:53:08 PM (7 years ago)
Author:
Rick van der Zwet
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Mendel3DPrinter

    v12 v13  
    108108
    109109Bed temperature reported using M105 was incorrect since power supply was faulty causing interference on the IC measuring the temperature. Replaced power supply, all happy again.
     110
     111My resistor bed consist of of 4 x 2R2 (WH10) in series resulting in 9 Ohm, PSU does not like this low load conditions or is simply broken which would make my 2nd dead power supply. The new PSU is only 12V which is not heating up properly. According to [https://en.wikipedia.org/wiki/Ohm%27s_law Ohm's law] (I = V/R or R = V/I or V = IR) and my resistor rating i get 1.3A, which in result would yield only (W = VI) 15.6W heating power, not sufficient since my total resistor capacity is 40W. Which would give me W = VI combined with V = IR becomes W = IRI. W=40, R=9, makes I = 2A. Which in result would require V to be 40W / 2A = 20V.